Abbreviations used:
HSE = Hueck Solar Energy, CSP = Concentrated Solar Power, PV = photovoltaics
Technology
Application
As a rule of thumb for using concentrated solar power (CSP), annual direct normal irradiance (DNI) of around 1,800 to 2,000 kWh/m² is assumed. Sites with higher DNI are advantageous; sites with lower DNI are less economical but still conceivable. A world map with DNI data is available, for example, from Solargis.
An HSE plant with a net rated electrical output of just over 100 kWel for daytime operation and up to 10 hours of storage operation requires roughly one hectare of plant area.
For heat applications, the net rated output per hectare—measured in kilowatts thermal (kWth)—is significantly higher. However, for a rough estimate it must be known how the electricity demand of such a plant is covered and whether space is required for this.
An HSE plant is suitable for electricity and/or heat supply. The application areas include not only all electricity applications and all industrial heat processes, but also cooling processes based on supplied heat.
Although thermal seawater desalination also appears conceivable, it should be noted that only coastal areas are suitable, where there is ample space and the air is largely clear.
The solar electricity generated is fed into the power grid or used autonomously in island mode. In both cases, complementary power generation by an HSE plant and an adjacent PV plant is beneficial.
Solar heat is provided in the form of hot air or as steam. The air temperature level can be set up to approx. 600–650°C, and the steam temperature level can be selected up to approx. 500–550°C. Lower temperatures are possible.
Island operation without a grid connection is possible. For continuous energy supply, it is advisable to combine PV with an HSE plant including thermal storage and, as standby, with iron as a renewable fuel.
In island mode, a separate PV power supply is required to start the fans and the pumps of the water–steam cycle. If the HSE plant is operated in island mode only for heat generation and entirely without a steam turbine and generator for self-supply, then batteries are also required for continuous operation of fans and pumps.
The concept of combining PV electricity, HSE electricity from the thermal storage of solar heat, and iron as a renewable fuel is scalable. In sunny regions, it is therefore also suitable for reliable and CO2-free power supply for data centers.
At present, conventional gas turbines or small modular nuclear reactors, which do not yet exist, are envisaged for supplying power to data centers. However, both technologies depend on fuels whose availability is uncertain in the medium and long term. In addition, there are follow-on problems due to CO2-containing exhaust gases from gas turbines or due to waste from operating nuclear reactors.
During maintenance of a nuclear power plant, the associated data center would have to be throttled back or shut down entirely if the temporarily unavailable, very large amount of electricity cannot be sourced elsewhere.
By contrast, with many small, modular plants based on renewable energy, individual blocks can be maintained without impairing the overall energy supply of a data center.
The concept described is also scalable to the extent that entire economies can be supplied reliably. Since iron as an energy carrier can be transported globally much more easily than hydrogen, a global energy supply for humanity would also be possible with this concept.
System
A solar thermal plant based on the HSE concept includes, among other things, the advantages listed below.
Some aspects are already addressed in brief on the “Overview” page:
- The concept can be fully industrialized, which is an essential prerequisite for achieving a competitive cost level.
- Air as the working fluid is safe, non-corrosive, and non-toxic.
- Due to the low system pressure, the plant does not fall under the Pressure Equipment Directive.
- The solid-state thermal storage has a much longer service life than lithium batteries.
- The system is suitable for heat and power generation.
- The rotors of the steam turbine and generator contribute to grid stabilization through their rotating masses.
- In the event of a complete loss of external energy supply, the system is fail-safe.
- The raw materials required to build the plants are available without limitation.
- With an air-cooled condenser for the water–steam cycle and intelligent mirror-cleaning methods, the water demand for operating an HSE plant is very low.
- Overall, the complexity of the solar thermal plant is low.
- Very high local value creation is possible.
In addition, the following advantages are significant:
- Only the solar thermal receiver is new; all other components are already established and bankable in terms of financing plant construction.
- The receiver design is robust and scalable.
- The receiver has very good technical performance data.
- For optimal part-load operation of the receiver, the cold-air mass flow of individual modules can be controlled individually.
- The ceramic material SiC enables receiver temperatures of over 1,000°C.
- The receiver contains no transparent components, such as quartz glass panes, that can become soiled.
- The receiver is closed to the environment and is therefore insensitive to contamination from the surroundings.
- The receiver contains no rapidly moving parts.
- Construction of the plant is not limited to horizontal areas for the solar field.
- Existing industrial heat processes can be partially or fully retrofitted to the HSE concept, provided there is sufficient space at a sunny site of the heat consumer.
In terms of operational safety, availability, and cost, air is the optimal heat transfer medium.
Without a computational design of the plant shown and without connecting air ducts, the following are shown on the ground in a highly simplified, schematic manner and clockwise:
- Solar tower
- Transformer building
- Air-cooled condenser
- Building for steam boiler, steam turbine, generator, and auxiliary systems
- Two air blowers
- Thermal storage modules as containers for solids
In addition, there is a low-loader and three passenger cars.

A semicircular solar field has the following advantages:
- For a heat application, a very short connection from the HSE plant to the heat consumer is possible.
- Due to the better angle of incidence, the heliostats (mirrors) on the side of the solar tower facing away from the sun have higher efficiency than heliostats that would be located on the opposite side.

In the plant shown, the size of the HSE receiver block supported by a steel structure is chosen so that it fits on a low-loader without being dismantled into individual parts. The loaded low-loader remains below the minimum clearance height of 4 meters. Under these boundary conditions, a semicircular shape was chosen for the solar receiver, because the inner area of a circular receiver would be too small. Accordingly, the solar field has the favorable semicircular shape that matches the receiver.
The radius of the solar field is 250 meters, resulting in a total area of about 10 hectares. The tower has a total height of 65 meters.
With continuous daytime operation and nighttime operation of up to 10 hours, the net rated electrical output is roughly estimated at just over 1 MWel.

For larger plants, multiple modular receiver blocks are assembled. Each individual receiver block retains suitable dimensions for transport on a low-loader.
The maximum plant size results from the economically feasible dimensions of the air blowers and air ducts. With suitable development stages, a net rated output on the order of 10 to 25 MWel is targeted.
These figures are preliminary and therefore non-binding.
See also “What are the advantages and disadvantages of small and large CSP tower plants?“
The minimum size of an HSE plant for electrical power generation is determined by the smallest possible size of a suitable steam turbine. This is on the order of less than 600 kWel.
The system diagram of the HSE plant shows the solar block, the thermal storage, the blowers, and the steam generator.

The solar tower power plant of Kraftanlagen München (KAM) on the site of the German Aerospace Center (DLR) in Jülich was built in 2007 to 2008 with an almost identical system configuration.
The only fundamental difference is the receiver design: the KAM receiver is open to the environment. Cold ambient air is drawn in and heated as it flows through the ceramic receiver. After releasing heat, the cooled air flows back to the receiver, where it exits to the environment and is only partially drawn in again.
With the closed HSE receiver, the risk of clogging by foreign matter from the environment is avoided.
The closed receiver can also be operated with slight overpressure if desired. This opens up the option of blowing the hot air into a heat process without having to extract it again from there.

Receiver

The HSE receiver uses the following technical-physical principles to achieve the best possible heat transfer from concentrated solar radiation to the air flowing inside:
- Cold air cools best. It is therefore routed to the tip of each individual receiver cap, because thermal radiation from the hot outer surface there is otherwise lost unused to the environment.
- The inner surface of a receiver cap is much larger than the outer surface in order to achieve good heat transfer to the flowing air.
- For this type of heat exchanger, the ceramic material silicon carbide (SiC) is very well suited. SiC ceramic has high temperature resistance on the order of 1,200 to 1,400°C, very good thermal conductivity, high strength, and low density.
- The receiver elements arranged closely next to each other deliberately form a highly jagged outer surface, so that the convective heat lossOn hot, vertical outer surfaces, an air flow forms that carries away part of the heat. This is called convective heat loss. If such a surface is smooth, a faster flow forms that carries away more heat than if such a surface is uneven. is lower than with a smooth outer surface.
- The areas further back in a receiver cap are cooled less effectively because the air has already heated up on its way inward. However, the heat radiated from the outer surfaces there is not lost entirely to the environment. Part of it hits an adjacent surface and is transferred from there to the cooling air inside. This is known as the efficiency-beneficial “cavity effect”.
- The outer surface of the receiver is black so that the highest possible proportion of the incident radiant energy is absorbed.

Most of the basic physical principles of a receiver for a solar thermal application described above were presented in 2008 by Prof. D. G. Kroger, University of Stellenbosch, South Africa, as the “Spiky Central Receiver Air Pre-heater” (SCRAP) (Kroger, 2008). As a technical application, integration into a Brayton cycle was proposed.
A further development of this approach in Stellenbosch aimed at a geometry in which the cooling air initially flowed through a gap along the tip of the module (Erasmus et al., 2020).
A similar concept for flow guidance in a receiver module, developed by RWTH Aachen University and the German company Solar Millennium AG, was presented to the specialist audience at the SolarPACES 2012 conference (Garbrecht et al., 2012). In addition, it was published in a specialist journal (Garbrecht et al., 2013). Molten salt was envisaged as the heat transfer medium.
At the Royal Institute of Technology in Stockholm, Sweden, a receiver module was also investigated in which the heat transfer medium was intended to cool its tip first (Wang & Laumert, 2018). The module was additionally clad on the outside. Here too, pressurized air for a Brayton cycle was envisaged as the heat transfer medium.
The basic principles of the HSE receiver were designed by Dr. Ulrich Hueck for unpressurized air as the heat transfer medium based on a hand sketch on 21 December 2018 without being aware of the similar approaches mentioned above.
The approaches mentioned are presented on pages 14 to 17 of the German-language final report for the joint project “SolarRetrofit“, with further explanations and figures.
References:
Kroger, D. G., 2008. Spiky Central Receiver Air Pre-heater (SCRAP), Stellenbosch, South Africa: Department of Mechanical and Mechatronic Engineering, University of Stellenbosch.
Erasmus, D. J., Lubkoll, M., Craig, K. J. & von Backström, T. W., 2020. Capability of a novel impingement heat transfer device for application in future solar thermal receivers. AIP Conference Proceedings, Vol. 2303, p. 030014.
Garbrecht, O., Al-Sibai, F., Kneer, R. & Wieghardt, K., 2012. Numerical Investigation of a New Molten Salt Central Receiver Design, s.l.: SolarPaces.
Garbrecht, O., Al-Sibai, F., Kneer, R. & Wieghardt, K., 2013. CFD simulation of a new receiver design for a molten salt solar power tower. Solar Energy, Vol. 90, pp. 94–106.
Wang, W. & Laumert, B., 2018. An axial type impinging receiver. Energy, August 11, Vol. 162, pp. 318–334.
Thanks to 3D printing with the ceramic material silicon carbide (SiC), the receiver has acquired shapes that were previously not manufacturable.
The sectional drawing shows the internal structure of a single receiver module. The air flowing in the cold-air channel enters the supply pipe from the left and flows from there to the tip of the receiver. The air is heated on the way back and then routed downward in the hot-air channel.
The vertical gray area on the left, shown only small, indicates the supporting steel wall of the cold-air channel. This steel wall holds the receiver modules, which are movably attached to it, in position.
The sectional drawing largely corresponds to a figure in the already published patent application.

+++Partial answer+++
A single receiver module is designed for a thermal output of 40 kWth. This applies to a temperature of 200 °C at the air inlet and a temperature of 700 °C at the air outlet.
These figures are preliminary and therefore non-binding.
If you would like to read the full answer because you are considering a collaboration with HSE, please contact us via the contact form.
A single receiver cap has a height of approx. 32 cm and a diameter of 23 cm, so it can be manufactured by 3D printing. In the longer term, it is planned to roughly double the size of a receiver module.

The receiver module shown in the photo has a length of approx. 75 cm and a weight of approx. 25 kg. Length and weight depend on the design of the width of the gray hot-air channel. The circular metal part on the left, on which the ceramic rear wall of the hot-air channel is supported, is a partial section of the large metallic wall of the cold-air channel.

The individual receiver modules are assembled into a pre-assembled receiver block. The dimensions of such a block are chosen so that road transport on a low-loader is possible. The receiver block shown in the figure has such dimensions, is semicircular in shape, consists of 330 modules, and delivers a thermal output of approx. 13 MWth. If the individual modules are enlarged, their number is reduced while the block size remains the same.
The radius of a receiver block can be adjusted. A larger receiver can be assembled from several individual blocks arranged next to and above one another at the top of a solar tower. The actually achievable maximum receiver size depends more on the available size of the required air blower and a sensible size of the air ducts than on the receiver design itself.
See also the answer to the question “Can larger plants be implemented?“.

With the following design principles, largely covered by the patent application, the thermal expansions of the receiver are taken into account:
- A spring element compensates for the different thermal expansions of the metallic inner tube compared to the ceramic outer tube.
- The left support of the outer tube is mounted movably in the rear wall of the hot-air channel on the left, which is formed by individual base plates.
- The right support of the outer tube is mounted movably in the right wall of the hot-air channel, which is formed by individual base plates.
- The base plates of the hot-air channel, which is formed from many identical elements, are sealed against each other but not rigidly fixed to one another.

Manufacturing in ceramic necessitates small components that are sealed against each other. A completely tight design is not possible. This sealing is sufficient for the system to function, even if a small amount of energy may be lost through minor leaks. Due to the system pressure of under 500 mbar, the receiver is not a pressure vessel.
In the seven receiver modules of the Synlight test facility, the air flow of each module is set by a fixed throttle plate so that the most homogeneous temperature distribution possible is achieved across all modules.
For flow distribution in a larger receiver, active control elements at module level are envisaged. Active control of the air flow will only be relevant for some of the modules. Such electrically driven components at the air inlet of the receiver modules will all look the same and can therefore be manufactured cost-effectively as a mass product.

A black surface absorbs more solar radiation than a light-colored surface.
After manufacturing, the SiC ceramic has a gray surface. It is coated with the temperature-resistant paint Pyromark® 2500, developed back in the 1960s. This improves the absorption coefficient from 0.856 to 0.969.
Another coating method yields a further improvement. The absorption coefficient of SiC samples coated differently is 0.982 after application of the coating, 0.978 after temperature exposure up to 1,000°C, and 0.961 after temperature exposure up to 1,200°C. This other coating method also promises significantly improved durability compared to Pyromark® 2500.

The ceramic and metallic components of the receiver will have a longer service life than the seals used in the receiver. To replace all seals, a receiver block consisting of many individual modules is completely replaced at night, so that this maintenance work does not reduce plant availability.
The design also makes it possible, if required, to replace a single defective receiver module within a receiver block almost completely without dismantling the adjacent modules.
Storage
A solid-state thermal storage system is planned, heated by hot air during the day to up to 700°C. The cold-air side is at approx. 200°C, with this temperature specification resulting from the requirements of the water–steam cycle.
When heating up or charging the thermal storage, a hot zone moves through the storage: while the storage material on the inlet side quickly reaches the high air temperature, the storage material on the outlet side remains relatively cold until the hot zone arrives there.
During discharge, the thermal storage is flowed through in the opposite direction. Only when the cold zone that is now spreading reaches the air outlet does the air temperature there drop and the storage is discharged.
There are various developers and manufacturers of solid-state thermal storage systems that appear suitable for the application described.
Thermal storage systems in CSP plants are typically sized for around 10 hours of rated-load operation. It is advisable to design the thermal storage so that the turbo set—consisting of steam turbine and generator—can be operated at least at low output around the clock. On the one hand, fewer starts extend the turbine’s service life; on the other, the power grid is stabilized by the rotating mass of the turbo set even at idle.
Against this background, for power generation in the HSE system, optimization is planned toward a storage size that allows continuous operation of the turbo set—if necessary only at idle—for one day.
More than one day without sunshine generally cannot be bridged by a CSP plant, because it is not sensible to size the thermal storage to the required capacity.
During such periods, however, supplementary firing with a renewable energy carrier can ensure continuous heat or power supply. See the passage below ” Is there a connection to renewable energy carriers such as hydrogen and iron?“.
Large PV plants are currently being equipped with large battery fields, mostly lithium batteries. The resulting levelized cost of electricity may appear very low at first glance. However, the following disadvantages should be considered:
- PV plants and batteries lack rotating inertial mass. They therefore contribute little to grid stability and create costs elsewhere for the grid stabilization that is absolutely necessary.
- With lithium batteries, recurring replacement is required every 10–15 years. This entails high resource consumption with a correspondingly high CO2 footprint.
- The costs of metallic raw materials for batteries are volatile and cannot be predicted for the future.
- With lithium batteries, failure of the cooling of a battery container standing in the sun not only leads to a significant reduction in service life, but also to a very high fire risk. Such a battery fire is virtually impossible to extinguish.
- With purchased batteries, the share of local value creation is very low and import dependency is very high.
None of these disadvantages apply to a CSP system with thermal storage.
Mirror field
The mirrors of a solar tower plant that track the sun on two axes are called heliostats. There are different design variants and types. Ambitious targets for cost reductions have been achieved.
The glass coating is primarily applied with a thin silver layer; the addition of aluminum is being investigated. Plastic heliostats are also conceivable. Finally, there is an approach for heliostats in which long-wave solar radiation—i.e., the infrared heat component—is reflected for a CSP application, while short-wave solar radiation—mainly visible light—penetrates to the rear wall of the heliostat and hits a PV module there for power generation.
For the HSE system, there is free choice of the most suitable and at the same time most cost-effective heliostats. Small heliostats are preferred so that repair and replacement of individual heliostats can be carried out with simple tools without the use of large installation machines.
The goal of modern heliostat cleaning is to minimize water consumption.
Heliostat cleaning is increasingly automated: mobile robots enclose a heliostat, clean the mirror surfaces, and immediately recover the distilled water used so that it can then be cleaned, desalinated, and reused.
A vibration excitation being developed for cleaning PV modules may be transferable to cleaning heliostats. It is also conceivable to use the downwash of a drone to remove dust from heliostats.
The service life of heliostats is roughly on the order of 20 years. The mirror surfaces are replaceable, while the supporting structure has an even longer service life.
Premature damage or malfunctions of individual heliostats do not impair the integrity of the overall system and can be remedied by repair or replacement.
Digitalization
The control system typically used for power plants is also used in a CSP plant.
Additional control functions for the solar block relate, among other things, to the sub-aspects addressed in the graphic.

TES = Thermal Energy Storage
Key geometric parameters of a receiver module and the positioning of the cooling pins inside were optimized in parallel using software whose model can be described as artificial intelligence.
Software is also planned for optimizing the overall system, simultaneously optimizing a large number of parameters, which constitutes a form of artificial intelligence.
In this respect, artificial intelligence is already highly relevant for HSE technology. Further fields of application for artificial intelligence are expected.
Some functions of this website, such as “Open all” and “Close all”, were programmed with the help of artificial intelligence.
Operating power plants can hardly be imagined as fully autonomous, because there are too many points where manual intervention may be required in case of doubt.
However, a large number of small solar thermal HSE plants can be operated from a single control room with a very high degree of automation. In the control system of the control room, all information on the operation of many plants is consolidated. Only when manual intervention is required does operating staff need to visit the affected plant.
Power grid
Rotating masses—such as in turbines or generators—act like a flywheel. If the power grid suddenly needs more or less power, these heavy rotating parts briefly compensate for fluctuations. In an emergency, they release or absorb energy without control technology having to intervene. This keeps the grid frequency stable and prevents outages from occurring as quickly.
There are two reasons why the grid frequency can change:
- If too little electricity is fed into the grid, the grid frequency drops; if too much electricity is fed into the grid, the grid frequency rises.
- As a result of a disturbance, the grid frequency oscillates around the setpoint. The grid frequency is briefly lower, then higher, then lower again, etc., without this being directly attributable each time to an oversupply or undersupply of electricity.
Rotating masses in the power grid have a damping effect on both of these effects, regardless of the cause of the damping: the mass simply continues to rotate at the ideal grid frequency due to its inertia.
An electronic system measures the grid frequency and calculates its response from it. However, after only one oscillation, such a system cannot know whether the frequency change occurred due to (1) or (2), so at least two or more oscillations must be measured to calculate the correct response. This means the response comes too late to keep the grid frequency stable using this method alone.
The exact cause of the major power outage on 28 April 2025 in Spain and Portugal has been largely clarified.
Earlier that same day, unusual oscillations of the grid frequency were observed. The outage then coincided with the faulty disconnection of large amounts of power. In the aftermath, Spain is operating more gas-fired power plants than before the outage and increased so that the average daily minimum output of gas-fired power plants by around 40% compared to the level before the outage. These plants stabilize the grid frequency with the inert masses of the rotors of their turbines and generators.
CSP plants with turbines and generators can stabilize the grid frequency in a very similar way, but CO2-free, thereby reducing the risk of power outages—such as on 28 April 2025 in Spain and Portugal.
Mass products
Key requirements for a CSP system to become a mass product are as follows:
- Industrial mass production must be possible for all sub-components of the system.
- On-site installation effort must be reducible in order to maximize industrial pre-fabrication.
- It must be deployable wherever there is high solar irradiance and sufficient space. For example, there should be no restriction to exclusively horizontal terrain.
- Only environmentally friendly operating media may be used in larger quantities. Therefore, there should be no liquids or gases present in significant quantities that are flammable, can be particularly corrosive, or whose leakage could harm the environment.
- In the event of a complete loss of external energy supply, the entire plant must transition to a safe operating state. Therefore, no operating media should be used that could damage the plant when cooling down to ambient temperature.
- Robust operation must also be possible in the presence of impurities in the ambient air. Therefore, a CSP plant should be closed to the environment on its hot side so that no foreign matter can enter the system uncontrollably and impair it.
- There must be no transparent objects whose soiling could jeopardize the integrity of the system.
- Minimal and long-term stable costs are required for very large and robust storage capacities. Therefore, the storage materials should be chosen so that their long-term availability at low cost is ensured and so that they are insensitive to environmental influences such as high temperatures, storms, and other natural events.
- Scalability for different plant sizes should be possible so that both relatively small and very large amounts of energy can be provided cost-effectively for different applications using the same industrial concept by converting solar energy.
- The system should be flexible with regard to the shares of heat and electricity, in order to enable heat-only consumption, electricity-only generation, and mixed forms of heat consumption and electricity generation cost-effectively with the same industrial concept.
- The system should have minimal water consumption, because water is scarce at sunny sites.
The following serious problems at major solar tower power plants have become publicly known:
- Damage and leaks in molten-salt thermal storage tanks:
- Gemasolar, Spain, 20 MW, 15 h storage
- Crescent Dunes, Nevada, USA, 110 MW, 10 h storage
- Noor III, Morocco, 150 MW, 7 h storage
- Cerro Dominador, Chile, 110 MW, 17.5 h storage
- Burn-through of the receiver cladding at the aforementioned Crescent Dunes plant in the USA.
- Damage to the molten-salt heated steam superheater at the aforementioned Crescent Dunes plant in the USA.
- Shutdown of the Ivanpah plant in California, USA, with three units of 126 MW and 2x 133 MW after only 11 years of operation, as no storage is available, such storage cannot be retrofitted due to the use of steam as a heat transfer medium, and the plant’s daytime power is not competitive against PV.
The problems mentioned above cannot occur with HSE technology.
Regarding a) The thermal storage in the HSE system is based on solids, is pressureless, and the heat transfer medium, air, is non-corrosive.
Regarding b) With a temperature resistance of over 1,000°C, the ceramic HSE receiver has a significantly higher temperature resistance than a steel receiver for molten salt.
Regarding c) In the HSE system, the steam generator and its superheater are heated with air. This is therefore a technology that has been proven in plant engineering for decades and is not a special design for liquid, corrosive salt.
Regarding d) HSE technology enables the use of thermal storage. Power generation can thus be shifted to the lucrative evening and night hours, while the solar heat is largely stored during the day.
Renewable Energy Carriers
The connection to renewable energy carriers exists in two respects:
- Production of renewable energy carriers
Regarding the nominal capacity of a plant for the electricity-based production of renewable energy carriers – such as hydrogen – there is either an oversupply or an undersupply of fluctuating PV power throughout the day. Some of these fluctuations can be balanced with power from wind turbines, but not completely. The utilization of plants for the production of renewable energy carriers – and thus their economic efficiency – improves significantly when a low-cost electricity supply always matches the required nominal capacity. This becomes possible with a combination of PV power, wind energy, and HSE power. - Use of a renewable energy source
During prolonged periods of cloud cover, the thermal storage of an HSE plant is no longer sufficient to maintain its operation. During such periods, supplementary firing with a renewable energy source can ensure a continuous supply of heat or electricity. Thermal supplementary firing with the renewable energy source iron is particularly promising.

For further information, see the section below “How does iron work as a renewable energy source?“
Iron burns CO2-free: Short video
The use of iron as a renewable energy source and its advantages are hardly known. Therefore, this process is described below in its main variant:
- Green hydrogen is produced from renewable energies:
2H2O + electricity ➜ 2H2 + O2 - With green hydrogen, oxygen is removed from oxidized (“rusted”) iron dust, producing pure iron and water vapor:
Fe2O3 + 3H2 ➜ 2Fe + 3H2O - The chemically reduced iron dust thus serves as an energy carrier.
- High temperatures are generated during the combustion / oxidation of the iron dust:
4Fe + 3O2 ➜ 2Fe2O3 + heat
This combustion process does not generate CO2. - The now oxidized (“rusted”) iron dust is captured and completely reused in a closed cycle.

The process has the following advantages in particular:
- The combustion of iron provides a controllable and at the same time renewable energy source that contributes to solving the problem of fluctuating energy generation from PV and wind.
- As a renewable energy source for the production of reduced iron dust, the great potential of solar energy in sun-rich regions can be utilized: PV during the day and CSP with thermal storage at night.
- The water as the starting product for the production of green hydrogen remains at the site of the reduced iron production and can be used there again for the production of green hydrogen. This solves the problem of the large quantities of distilled water required for the production of green hydrogen.
- The reduced iron dust can be safely transported without pressure at ambient temperature and has an energy density that is many times higher than that of hydrogen. This solves the problem of worldwide transport of very large quantities of renewable energy.
- The energy carrier iron can be traded and transported globally. This results in less dependence on individual suppliers than inevitably arises with pipelines or power lines.
- The reduced iron dust can be burned at high temperatures in coal-fired power plants and industrial facilities, which only need to be adapted in a few components. This makes it possible to continue using existing infrastructure worldwide for future renewable energy and power generation, which can result in social and financial benefits.
- No special metallic materials are used for storing energy in iron, for which a shortage and thus a significant price increase is to be feared, such as lithium, cobalt, and copper for batteries.
Metalot Foundation: Metal Power Community
TU Darmstadt:
- Metal Energy Hub platform for metal-based energy storage
- “Clean Circles” project
EWI Cologne:
- Decarbonization: Iron as an Energy Source Could Help Reduce Costs
- Iron as an Energy Carrier: Assessing the Potential of an Additional Decarbonization Option for a Secure and Affordable Net-Zero System
Renewable Iron Fuel Technology (RIFT):
- Startup: Iron Fuel Technology built for impact
- EU-Startups: Backed by €113.8 million, Dutch startup RIFT to deliver 340 GWh of industrial heat annually and avoid over 1 million tonnes of CO2
HSE is not involved in the development of this technology, but thermal supplementary firing with the renewable energy carrier iron is very interesting for HSE plants.
See: “Could data centers and even entire economies be supplied reliably?“

Hydrogen at 700 bar, ammonia at -34°C. Source: Metal Energy Hub
The company Hydrosolid promises the storage of hydrogen in a nanopolymer solid at 35 bar with 3 kWh per liter.
Comparison
The table below summarizes technical approaches to balance non-controllable PV power. Column 2 contains the main disadvantages and Column 3 names the associated advantages of HSE technology.
|
Technology |
Disadvantages of the technology |
Advantages of the HSE system |
|---|---|---|
|
Lithium batteries |
|
|
|
Gas turbines |
|
|
|
Hydrogen for power generation |
|
|
|
Other CSP technologies |
|
|
|
PV power for heating thermal storage |
|
|
|
|

The plant size of 15 MWel in the figure serves for the visual comparison of 1 x 105 MWel = 7 x 15 MWel. For further information see ” Can larger plants be implemented?“
In hazy air, CSP parabolic trough plants have an advantage over solar tower plants: The widely distributed receiver tubes are located in the focal line of the trough-shaped mirrors. Therefore, the distance that the reflected solar radiation must travel from the mirror to the receiver is very short.
In solar tower plants, the reflected solar radiation from the mirrors to the receiver must take a much longer, almost horizontal path through the hazy air. In the process, some energy is lost to the suspended particles in the air.

The material expenditure for construction and the effort for operating a solar tower plant, on the other hand, is significantly lower than for a parabolic trough plant: In a solar tower plant, the mirror field is simpler to build, the wind loads on the mirrors are lower, and the effort for pumping the heat transfer medium through a very widely branched piping system, which must be completely leak-proof, is eliminated.
The large site for a parabolic trough plant must be horizontal with a gradient of no more than 3%. Otherwise, the flow of the thermal oil as a heat transfer medium would be uneven, because the flow of low-viscosity oil in the pipes could be interrupted when flowing downhill. Many sites that would actually be suitable for a CSP plant are excluded for the construction of a parabolic trough plant for this reason. The mirror field of a solar tower plant, on the other hand, is not restricted to a horizontal surface.
Assessment
The disadvantages of the HSE system are noted in Chapter 7.4 of the final report on the publicly funded project and are reproduced here in updated form:
A YouTube video by Deutsche Welle comprehensively examined the potential of CSP for providing solar energy during the night (DW Planet A, 2024).
A comment on this video then stated:
“The problem with CSP is that they sacrifice economics and complexity to the god of collection efficiency. If you can reduce the efficiency by 10-20% and half the cost, you have a more economic viable solution. (…)” (@MichaelDobbins, 07/2024)
Translation:
“The problem with CSP is that economics and complexity are sacrificed to the god of efficiency. If you can reduce the efficiency by 10-20% and halve the costs, you have a more economical solution. (…)”
When using pressureless air as a heat transfer medium, it generally applies that the energy expenditure for transporting this air at comparable process temperatures forces a slightly lower overall efficiency of the solar system than can theoretically be achieved in CSP plants with heat transfer media such as molten salt or liquid sodium or at the very high temperatures of particle receivers.
Namely, either the maximum possible thermal efficiency of the air receiver is bought at the price of a high electrical fan power, or the pressure loss and the associated fan power are reduced, which in turn results in a slightly lower thermal efficiency of the receiver.
However, two aspects put the slightly lower overall efficiency in nominal load operation of a solar thermal air system into perspective:
- The electrical self-consumption for operating the receiver only occurs during the day, when PV delivers cheaper electricity anyway than CSP is able to. If, on the other hand, air only flows through the thermal storage at night, then the electrical self-consumption of the CSP plant is significantly lower. At the same time, the extra net CSP electricity generated at night can be sold at better prices because PV does not deliver directly generated and thus low-cost electricity.
- During the night, sun-rich, cloudless desert regions cool down significantly. With the lower outside temperature, the effectiveness of an air-cooled condenser in the water-steam cycle of a CSP plant increases, which in turn enables a more favorable operating point for the steam turbine and thus more power generation.
The remaining, minor disadvantage in overall efficiency is balanced by the cost advantages due to the simplicity and robustness of the solar thermal air system as well as by cost reductions in industrial series production.
The limitation of the construction size of solar thermal plants with pressureless air as a large-volume heat transfer medium is also countered on the cost side through standardization and industrialization.
Technology Readiness Level (TRL) 4 was achieved with successful tests on a single receiver module:
“Technology validated in lab” (EU definition)
“Component and/or breadboard validation in laboratory environment” (NASA definition)
Technology readiness level 5 is defined as follows:
“Technology validated in relevant environment (industrially relevant environment in the case of key enabling technologies)” (EU definition)
“Component and/or breadboard validation in relevant environment” (NASA definition)
In the sense of TRL 4-5, the tests in the “Synlight” artificial sun of the DLR in Jülich resulted in a further validation with several modules at the nominal capacity of the receiver.
Business Model
Value Creation
The HSE system is in large parts very simple plant engineering, which enables an extraordinarily high local value creation.

As a service concept for HSE plants, “roll-in / roll-out” makes sense: None of the larger components are maintained on site. Instead, they are simply replaced for maintenance and then efficiently and cost-effectively repaired in specialized workshops.
Intellectual Property Rights
The German intellectual property application “Solar thermal module” (10 2022 209 642.8) was filed on September 14, 2022, with disclosure on March 14, 2024.
The identical European intellectual property application “Solar thermal module” (PCT/EP2023/075004) was filed on time on September 12, 2023.
In March and April 2025, intellectual property rights were filed on time by Hueck Solar Energy GmbH worldwide in all countries and regions relevant to solar thermal energy.

The 11 patent claims of the patent family refer to the following sub-aspects of the solar thermal module:
- Three constructive solutions for the technical handling of thermal expansion using a spring element (51), articulated connections (34, 35), and the mechanical decoupling of components expanding differently (36, 37).
- The assignment of metallic and ceramic materials to specific functional areas (5, 30) of the solar thermal module.
- A specific aspect of the flow guidance in the air outlet area (36, 37) of a solar thermal module.
- The constructive design of the positive locking anti-rotation device (42) for the screw connections (39, 41) inside a receiver module.
- The use of bayonet locks on three components (44, 46, 47) of the solar thermal module.
- The use of an outer tube (49) for the supply of cold air in an inner tube (48) through the hot air duct (6).
- The process for obtaining thermal energy from solar radiation for a heat consumer with the help of many such solar thermal modules (15).

Yes, the entire plant configuration is protected by the intellectual property applications.
For an industrializable solar tower plant with pressureless air as a heat transfer medium, a receiver closed to the environment is required that contains no transparent objects such as quartz glass panes. Anyone who wants to develop or use such a receiver with good thermal efficiency themselves will, in the assessment of the main inventor, find no deviating construction principles that are not covered by the patent claims.
Market
Potential customers are all medium and large consumers of electricity in sun-rich regions. In addition, there are all medium and large heat consumers there, provided there is enough space for a solar thermal plant in the vicinity of the heat demand.
The explanations for the question below should be noted: “Which partners are needed for the market launch?”
For a customer who wants to obtain electricity or heat from an HSE system, the handling must be very simple. This means that a customer neither finances or builds such a plant himself, nor operates it himself, but merely pays for the energy quantities consumed.
The explanations for the question below should be noted: “Which partners are needed for the market launch?”
The yield of PV systems follows a daily curve. If you transfer their area to a rectangle with the height of the peak power of the systems, then the width of this rectangle corresponds to the so-called “Peak Sun Hours”. Their period is – depending on the location – on annual average about 5 to 7 hours per day. If the peak power of the systems corresponds to the average demand of the electricity consumers, then the remaining time of 17 to 19 “peak hours” per day must be provided either from PV electricity stored elsewhere or from other energy systems.
In a completely CO2-free energy supply, which largely dispenses with stationary electrical batteries due to the enormous resource consumption and the fire hazard, an industrialized and thus cost-effective CSP technology in sun-rich regions is predestined to cover most of these 17 to 19 hours per day: for power generation, heat generation, and the production of suitable renewable energy carriers that can be used globally.
Against this background, CSP has at least as much, if not even greater, market potential than PV.
Partners
+++Partial answer+++
The essential partner for the market launch of the HSE system is an "Energy Service Company," which in terms of status can be an "Independent Power Producer" (IPP), an energy supplier, or another type of high-performance company in the energy business.
If you would like to read the full answer because you are considering a collaboration with HSE, please contact us via the contact form.
Omterra's withdrawal from the solar project was based on a portfolio decision and strategy adjustment.
The final report dated 30 September 2024 on the joint project “SolarRetrofit – Solar thermal heat for power plants and industry” funded by the Federal Ministry for Economic Affairs and Energy (BMWE) of Omterra Global GmbH & Co. KG and the Institute of Solar Research of the German Aerospace Center (DLR) was published by the Technical Information Library (TIB) Hannover. The report comprises 159 pages with 179 illustrations, 22 tables, and 41 references.
Environment
Living Beings
In HSE plants, there are no flammable, toxic, or radioactive substances and no other dangers for residents. In addition, solar thermal power plants are built in sun-rich locations where there are practically no residents.
Large solar tower plants can become a deadly danger for birds. The very hot, centrally located receiver is not the problem, as its heat radiation instinctively prevents birds from approaching it. However, the energy density of the concentrated solar radiation in the air, which increases towards the receiver, is dangerous and cannot be perceived by birds in time, so that they burn in flight. In large solar tower plants, this area is so large that the deterrent effect of the receiver’s heat radiation does not reach far enough.
In small solar tower plants, the area dangerous for birds is correspondingly smaller. Thus, the heat radiation of the receiver, whose temperature corresponds approximately to the temperature of a large plant and is perceived by birds in time, still reaches far enough to keep birds from flying into the area of high energy density that is dangerous for them.
If this effect is no longer sufficient in a medium-sized plant, then other remedial measures are required: With cameras and image evaluation by artificial intelligence, the approach of birds is recognizable. If birds approach the danger zone, a deterrent is used. In addition, the defocusing of some of the heliostats can cause the dangerous energy density in the air to prevail only in an area that birds avoid anyway.
During the construction of a solar thermal plant, the sparse biosphere is burdened, but it recovers from it without problems. After construction, the heliostats become shade providers in the glowing heat of the day. This positive effect can contribute to the diversification of the local biosphere.
Space Requirement
Solar thermal plants are intended for sun-rich desert regions. There is no space problem there. This is pleasingly different from the construction of wind turbines on land, the construction of dams, or the large-scale cultivation of biomass, which very often involves conflicts over the required space.
Once again the quote noted on the page “Overview“: “The earth’s deserts receive more energy from the sun in six hours than humanity consumes in an entire year.” For the energy supply of all humanity, less than 0.3% of the existing desert areas must therefore be built on with solar plants. This is not a danger to the environment.
The desertification, i.e., desert expansion, on the other hand, is about 0.1-0.3% of the desert area per year.
Raw Materials
For HSE plants, largely no raw materials are required for which a shortage is to be feared. A shortage is only possible for the copper required for the windings of the generators, but copper can be recycled very well.
The required raw material silicon carbide (SiC) is produced artificially, is based on the elements silicon (Si) and carbon (C), and is thus available in unlimited quantities.
Operating Materials
The answers to the question “How are the heliostats cleaned?” include information on minimizing water consumption for mirror cleaning.
There are CSP plants with water-cooled condensers. Their water consumption is enormously high. HSE plants for power generation, on the other hand, receive an air-cooled condenser that consumes no water. Since it gets very cold at night in deserts with clear air, an air-cooled condenser can be used very well there. During the day, when PV power is unbeatably cheap, the efficiency of an air-cooled condenser plays no role. Instead of power generation, the solar heat is primarily stored.
The steam cycle of a steam turbine plant is closed. Only the minor water losses must be replaced by demineralized water.
No operating materials are required on a larger scale for the ongoing operation of an HSE plant.
Feedback
If you have a question in connection with HSE technology that is not asked and answered here, you are welcome to send this question to HSE.
The details of HSE technology presented here are either already included in the disclosure of the intellectual property application, can be found in the final report on a public funding project, or are published elsewhere.
|
|
Template
Template center
Text

Text

Text